File

GNUmakefile @ 10571:cfeb0077c9e9

net.server_epoll: Avoid concatenating buffer with single item Saves creating a string that'll be identical to buffer[1] anyways, as well as a C function call. Depending on Lua version and length of the string, this could be reusing an interned string, but a longer one would probably be duplicated for no reason. Having exactly one item in the buffer seems like it would be fairly common, but I have not done an extensive study. If opportunistic writes are enabled then it will be even more likely. This special case could be optimized like this in table.concat but it does not look like it is.
author Kim Alvefur <zash@zash.se>
date Sat, 28 Dec 2019 06:18:58 +0100
parent 10260:d6b9cacfef76
child 10879:5c7bb2440f53
line wrap: on
line source


include config.unix

BIN = $(DESTDIR)$(PREFIX)/bin
CONFIG = $(DESTDIR)$(SYSCONFDIR)
MODULES = $(DESTDIR)$(LIBDIR)/prosody/modules
SOURCE = $(DESTDIR)$(LIBDIR)/prosody
DATA = $(DESTDIR)$(DATADIR)
MAN = $(DESTDIR)$(PREFIX)/share/man

INSTALLEDSOURCE = $(LIBDIR)/prosody
INSTALLEDCONFIG = $(SYSCONFDIR)
INSTALLEDMODULES = $(LIBDIR)/prosody/modules
INSTALLEDDATA = $(DATADIR)

INSTALL=install -p
INSTALL_DATA=$(INSTALL) -m644
INSTALL_EXEC=$(INSTALL) -m755
MKDIR=install -d
MKDIR_PRIVATE=$(MKDIR) -m750

LUACHECK=luacheck
BUSTED=busted
SCANSION=scansion

.PHONY: all test coverage clean install

all: prosody.install prosodyctl.install prosody.cfg.lua.install prosody.version
	$(MAKE) -C util-src install
ifeq ($(EXCERTS),yes)
	-$(MAKE) -C certs localhost.crt example.com.crt
endif

install: prosody.install prosodyctl.install prosody.cfg.lua.install util/encodings.so util/encodings.so util/pposix.so util/signal.so
	$(MKDIR) $(BIN) $(CONFIG) $(MODULES) $(SOURCE)
	$(MKDIR_PRIVATE) $(DATA)
	$(MKDIR) $(MAN)/man1
	$(MKDIR) $(CONFIG)/certs
	$(MKDIR) $(SOURCE)/core $(SOURCE)/net $(SOURCE)/util
	$(INSTALL_EXEC) ./prosody.install $(BIN)/prosody
	$(INSTALL_EXEC) ./prosodyctl.install $(BIN)/prosodyctl
	$(INSTALL_DATA) core/*.lua $(SOURCE)/core
	$(INSTALL_DATA) net/*.lua $(SOURCE)/net
	$(MKDIR) $(SOURCE)/net/http $(SOURCE)/net/resolvers $(SOURCE)/net/websocket
	$(INSTALL_DATA) net/http/*.lua $(SOURCE)/net/http
	$(INSTALL_DATA) net/resolvers/*.lua $(SOURCE)/net/resolvers
	$(INSTALL_DATA) net/websocket/*.lua $(SOURCE)/net/websocket
	$(INSTALL_DATA) util/*.lua $(SOURCE)/util
	$(INSTALL_DATA) util/*.so $(SOURCE)/util
	$(MKDIR) $(SOURCE)/util/sasl
	$(INSTALL_DATA) util/sasl/*.lua $(SOURCE)/util/sasl
	$(MKDIR) $(MODULES)/mod_s2s $(MODULES)/mod_pubsub $(MODULES)/adhoc $(MODULES)/muc $(MODULES)/mod_mam
	$(INSTALL_DATA) plugins/*.lua $(MODULES)
	$(INSTALL_DATA) plugins/mod_s2s/*.lua $(MODULES)/mod_s2s
	$(INSTALL_DATA) plugins/mod_pubsub/*.lua $(MODULES)/mod_pubsub
	$(INSTALL_DATA) plugins/adhoc/*.lua $(MODULES)/adhoc
	$(INSTALL_DATA) plugins/muc/*.lua $(MODULES)/muc
	$(INSTALL_DATA) plugins/mod_mam/*.lua $(MODULES)/mod_mam
	$(INSTALL_DATA) certs/* $(CONFIG)/certs
	$(INSTALL_DATA) man/prosodyctl.man $(MAN)/man1/prosodyctl.1
	test -f $(CONFIG)/prosody.cfg.lua || $(INSTALL_DATA) prosody.cfg.lua.install $(CONFIG)/prosody.cfg.lua
	-test -f prosody.version && $(INSTALL_DATA) prosody.version $(SOURCE)/prosody.version
	$(MAKE) install -C util-src

clean:
	rm -f prosody.install
	rm -f prosodyctl.install
	rm -f prosody.cfg.lua.install
	rm -f prosody.version
	$(MAKE) clean -C util-src

test:
	$(BUSTED) --lua=$(RUNWITH)

integration-test: all
	$(MKDIR) data
	$(RUNWITH) prosodyctl --config ./spec/scansion/prosody.cfg.lua start
	$(SCANSION) -d ./spec/scansion; R=$$? \
	$(RUNWITH) prosodyctl --config ./spec/scansion/prosody.cfg.lua stop \
	exit $$R

coverage:
	-rm -- luacov.*
	$(BUSTED) --lua=$(RUNWITH) -c
	luacov
	luacov-console
	luacov-console -s
	@echo "To inspect individual files run: luacov-console -l FILENAME"

lint:
	$(LUACHECK) -q $$(HGPLAIN= hg files -I '**.lua') prosody prosodyctl
	@echo $$(sed -n '/^\tlocal exclude_files/,/^}/p;' .luacheckrc | sed '1d;$d' | wc -l) files ignored
	shellcheck configure

util/%.so:
	$(MAKE) install -C util-src

%.install: %
	sed "1s| lua$$| $(RUNWITH)|; \
		s|^CFG_SOURCEDIR=.*;$$|CFG_SOURCEDIR='$(INSTALLEDSOURCE)';|; \
		s|^CFG_CONFIGDIR=.*;$$|CFG_CONFIGDIR='$(INSTALLEDCONFIG)';|; \
		s|^CFG_DATADIR=.*;$$|CFG_DATADIR='$(INSTALLEDDATA)';|; \
		s|^CFG_PLUGINDIR=.*;$$|CFG_PLUGINDIR='$(INSTALLEDMODULES)/';|;" < $^ > $@

prosody.cfg.lua.install: prosody.cfg.lua.dist
	sed 's|certs/|$(INSTALLEDCONFIG)/certs/|' $^ > $@

%.version: %.release
	cp $^ $@

%.version: .hg_archival.txt
	sed -n 's/^node: \(............\).*/\1/p' $^ > $@

%.version: .hg/dirstate
	hexdump -n6 -e'6/1 "%02x"' $^ > $@

%.version:
	echo unknown > $@