Software /
code /
prosody
File
spec/utf8_sequences.txt @ 11516:83822be7704d
util.xmppstream: Send <?xml?> declaration in same call as stream open
If network_settings.opportunistic_writes is enabled then this would
previously have resulted in two socket writes, and possibly two packets
being sent. This caused some issues in older versions of Gajim, which
apparently expected the stream opening in the first packet, and thus it
could not connect.
With this change and opportunistic_writes enabled, the first packet
should contain both the xml declaration and the stream open tag.
Without opportunistic_writes, there should be no observable change.
Tested with Gajim 1.1.2 (on same machine). Unsure if loopback behaves
differently than the network here.
author | Kim Alvefur <zash@zash.se> |
---|---|
date | Wed, 14 Apr 2021 15:21:13 +0200 |
parent | 8236:4878e4159e12 |
line wrap: on
line source
Should pass: 41 42 43 # Simple ASCII - abc Should pass: 41 42 c3 87 # "ABÇ" Should pass: 41 42 e1 b8 88 # "ABḈ" Should pass: 41 42 f0 9d 9c 8d # "AB𝜍" Should pass: F4 8F BF BF # Last valid sequence (U+10FFFF) Should fail: F4 90 80 80 # First invalid sequence (U+110000) Should fail: 80 81 82 83 # Invalid sequence (invalid start byte) Should fail: C2 C3 # Invalid sequence (invalid continuation byte) Should fail: C0 43 # Overlong sequence Should fail: F5 80 80 80 # U+140000 (out of range) Should fail: ED A0 80 # U+D800 (forbidden by RFC 3629) Should fail: ED BF BF # U+DFFF (forbidden by RFC 3629) Should pass: ED 9F BF # U+D7FF (U+D800 minus 1: allowed) Should pass: EE 80 80 # U+E000 (U+D7FF plus 1: allowed) Should fail: C0 # Invalid start byte Should fail: C1 # Invalid start byte Should fail: C2 # Incomplete sequence Should fail: F8 88 80 80 80 # 6-byte sequence Should pass: 7F # Last valid 1-byte sequence (U+00007F) Should pass: DF BF # Last valid 2-byte sequence (U+0007FF) Should pass: EF BF BF # Last valid 3-byte sequence (U+00FFFF) Should pass: 00 # First valid 1-byte sequence (U+000000) Should pass: C2 80 # First valid 2-byte sequence (U+000080) Should pass: E0 A0 80 # First valid 3-byte sequence (U+000800) Should pass: F0 90 80 80 # First valid 4-byte sequence (U+000800) Should fail: F8 88 80 80 80 # First 5-byte sequence - invalid per RFC 3629 Should fail: FC 84 80 80 80 80 # First 6-byte sequence - invalid per RFC 3629 Should pass: EF BF BD # U+00FFFD (replacement character) Should fail: 80 # First continuation byte Should fail: BF # Last continuation byte Should fail: 80 BF # 2 continuation bytes Should fail: 80 BF 80 # 3 continuation bytes Should fail: 80 BF 80 BF # 4 continuation bytes Should fail: 80 BF 80 BF 80 # 5 continuation bytes Should fail: 80 BF 80 BF 80 BF # 6 continuation bytes Should fail: 80 BF 80 BF 80 BF 80 # 7 continuation bytes Should fail: FE # Impossible byte Should fail: FF # Impossible byte Should fail: FE FE FF FF # Impossible bytes Should fail: C0 AF # Overlong "/" Should fail: E0 80 AF # Overlong "/" Should fail: F0 80 80 AF # Overlong "/" Should fail: F8 80 80 80 AF # Overlong "/" Should fail: FC 80 80 80 80 AF # Overlong "/" Should fail: C0 80 AF # Overlong "/" (invalid) Should fail: C1 BF # Overlong Should fail: E0 9F BF # Overlong Should fail: F0 8F BF BF # Overlong Should fail: F8 87 BF BF BF # Overlong Should fail: FC 83 BF BF BF BF # Overlong Should pass: EF BF BE # U+FFFE (invalid unicode, valid UTF-8) Should pass: EF BF BF # U+FFFF (invalid unicode, valid UTF-8)