Software /
code /
prosody
File
spec/utf8_sequences.txt @ 13744:34ac05f6bd10 13.0
core.configmanager: Fix reporting delayed warnings from global section
A Credential in the global section would be stored at
delayed_warnings["*/secret"], but get("example.com","secret") would look
for delayed_warnings["example.com/secret"]
Storing the warnings in the config itself has the unfortunate
side-effect that the config now contains util.error objects, which may
be awkward if something bypasses get(). Should rawget() also do this
filtering? getconfig() too?
Currently this only affects prosodyctl, so maybe it won't be much of a
problem.
author | Kim Alvefur <zash@zash.se> |
---|---|
date | Sat, 22 Feb 2025 00:08:18 +0100 |
parent | 8236:4878e4159e12 |
line wrap: on
line source
Should pass: 41 42 43 # Simple ASCII - abc Should pass: 41 42 c3 87 # "ABÇ" Should pass: 41 42 e1 b8 88 # "ABḈ" Should pass: 41 42 f0 9d 9c 8d # "AB𝜍" Should pass: F4 8F BF BF # Last valid sequence (U+10FFFF) Should fail: F4 90 80 80 # First invalid sequence (U+110000) Should fail: 80 81 82 83 # Invalid sequence (invalid start byte) Should fail: C2 C3 # Invalid sequence (invalid continuation byte) Should fail: C0 43 # Overlong sequence Should fail: F5 80 80 80 # U+140000 (out of range) Should fail: ED A0 80 # U+D800 (forbidden by RFC 3629) Should fail: ED BF BF # U+DFFF (forbidden by RFC 3629) Should pass: ED 9F BF # U+D7FF (U+D800 minus 1: allowed) Should pass: EE 80 80 # U+E000 (U+D7FF plus 1: allowed) Should fail: C0 # Invalid start byte Should fail: C1 # Invalid start byte Should fail: C2 # Incomplete sequence Should fail: F8 88 80 80 80 # 6-byte sequence Should pass: 7F # Last valid 1-byte sequence (U+00007F) Should pass: DF BF # Last valid 2-byte sequence (U+0007FF) Should pass: EF BF BF # Last valid 3-byte sequence (U+00FFFF) Should pass: 00 # First valid 1-byte sequence (U+000000) Should pass: C2 80 # First valid 2-byte sequence (U+000080) Should pass: E0 A0 80 # First valid 3-byte sequence (U+000800) Should pass: F0 90 80 80 # First valid 4-byte sequence (U+000800) Should fail: F8 88 80 80 80 # First 5-byte sequence - invalid per RFC 3629 Should fail: FC 84 80 80 80 80 # First 6-byte sequence - invalid per RFC 3629 Should pass: EF BF BD # U+00FFFD (replacement character) Should fail: 80 # First continuation byte Should fail: BF # Last continuation byte Should fail: 80 BF # 2 continuation bytes Should fail: 80 BF 80 # 3 continuation bytes Should fail: 80 BF 80 BF # 4 continuation bytes Should fail: 80 BF 80 BF 80 # 5 continuation bytes Should fail: 80 BF 80 BF 80 BF # 6 continuation bytes Should fail: 80 BF 80 BF 80 BF 80 # 7 continuation bytes Should fail: FE # Impossible byte Should fail: FF # Impossible byte Should fail: FE FE FF FF # Impossible bytes Should fail: C0 AF # Overlong "/" Should fail: E0 80 AF # Overlong "/" Should fail: F0 80 80 AF # Overlong "/" Should fail: F8 80 80 80 AF # Overlong "/" Should fail: FC 80 80 80 80 AF # Overlong "/" Should fail: C0 80 AF # Overlong "/" (invalid) Should fail: C1 BF # Overlong Should fail: E0 9F BF # Overlong Should fail: F0 8F BF BF # Overlong Should fail: F8 87 BF BF BF # Overlong Should fail: FC 83 BF BF BF BF # Overlong Should pass: EF BF BE # U+FFFE (invalid unicode, valid UTF-8) Should pass: EF BF BF # U+FFFF (invalid unicode, valid UTF-8)